Φασματοφωτόμετρο Ατομικής Απορρόφησης πλήρες. Φλόγα, Φούρνος γραφίτη & αυτόματος δειγματολήπτης




<br />



Φασματοφωτόμετρο Ατομικής Απορρόφησης πλήρες, με τεχνικές Φλόγας & Φούρνου γραφίτη, αυτόματος δειγματολήπτης.


Χαρακτηριστικά - Τεχνικές Προδιαγραφές

1. Innovated rich oxygen air-acetylene flame analysis technique:

 

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950 with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

 

2. Integrated flame/graphite furnace atomization system, changeable with flame emission burner;

 

- 2.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor

- 2.2 A flame emission burner head can be installed to perform flame emission analysis to akali metais as K, Na etc.

 

3. Accurate fully automated control system

 

- 3.1 Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position

- 3.2 Automatic wavelength scanning and peak picking

- 3.3 Automatic spectral bandwidth changing

- 3.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, automatic ignition and automatic gas flow setting

 

4. Reliable fully automatic graphite furnace analysis

 

- 4.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%

- 4.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

- 4.3 Multi-function autosampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis

 

5. Perfect safety protection measures

 

- 5.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

- 5.2 Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system

 

6. Advance and reliable electronic design

 

- 6.1 Adopting large-scale programmable logic array and Inter I2C bus technology

- 6.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

 

7. Easy and practical analysis software

 

- 7.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization

- 7.2 Automatic sample dilution, automatic curve fitting, automatic sensitivity correction

- 7.3 Auotmatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation

- 7.4 Mutil-elements determination in sequence to the same sample

- 7.5 Measured data and final results can be printed out and edited in Excel format

 

 

Main Specification :

 

Wavelength range : 190-900nm

Wavelength accuracy Better than ±0.25nm

Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

Baseline stability 0.004A/30min

Background correction

The D2 lamp background correction capability at 1A is better than 30 times

The S-H background correction capability at 1.8A is better than 30 times.

 

Light Source System Lamp turret Motorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.);

Lamp current adjustment Wide pulse current: 0~25mA,

 Narrow pulse current: 0~10mA

Lamp power supply mode

400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse

 

Optical System Monochomator Single beam, Czerny-Turner design grating monochromator

Grating 1800 l/mm

Focal length 277mm

Blazed Wavelength 250nm

Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over

Flame Atomizer Burner 10cm single slot all-titanium burner

Spray chamber Corrosion resistant all-plastic spray chamber

Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

Emission burner provided

Graphite Furnace Temperature range Room temperature~3000ºC

Heating rate 2000/s

Graphite tube dimensions 28mm(L)×8mm(OD)

Characteristic mass Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g

Precision Cd≤3%, Cu≤3%, Mo≤4%

Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.

Software Under Windows operating system

Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.

Repeat times 1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.

Multi-task Functions Sequential measurement for multi-element determination to the same sample

Condition reading With model function

Result printing Measurement data and final analytical report printout, editing with Excel

Standard RS-232 serial port communication

Graphite Furnace Autosample Sample tray capacity 55 sample vessels and 5 reagent vessels

Vessel materia Polypropylene

Vessel volume 3ml for sample vessel, 20ml for reagent vessel

Minimum sampling volume 1μl

Repeatable sampling times 1 -99 times

Sampling system Accurate dual pump system, with 100μl and 1ml injiectors

Characteristic Concentration and Detection Limit

Air-C2H2 flame

 

Oxygen-rich Air-C2H2 flame

- Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;

- Ba:  Characteristic concentration ≤ 0.22mg/L

- Al:   Characteristic concentration ≤ 0.4mg/L

Function Expansion

Hydride vapor generator can be connected for hydride analysis

 

Dimensions and weight Main unit 107×49×58cm, 140kg

Graphite furnace 42×42×46cm, 65kg

Autosampler 40×29×29cm, 15kg

 



ΤΙΜΗ:
37174,18 €
Συμπεριλαμβάνεται ο ΦΠΑ

Κατόπιν Παραγγελίας

Το μήνυμα σας εστάλη με επιτυχία
Η διαδικασία δεν μπορεί να ολοκληρωθεί.
Εισάγετε όνομα
Σημείωση: Όλα τα πεδία είναι υποχρεωτικά
Εισάγετε τηλέφωνο
Εισάγετε το μήνυμα σας
  • Τεχνικές Προδιαγραφές
  • Εγχειρίδιο Χρήσης
  • Αρχεία
  • Σχετικές Πληροφορίες
ΠΡΟΤΕΙΝΟΜΕΝΑ ΠΡΟΙΟΝΤΑ